ASR-920-24SZ-M Specifications

Physical specifications1

(H x W x D)

1.72 x 17.5 x 10 in. (43.7 x 444.5 x 255 mm), 1RU
Weight 8.5 lb (3.9kg) – empty chassis
Rack mounts ETSI rack-mount kit

19-in. rack-mount kit

23-in. rack-mount kit

Air flow Front-to-Back & Side-to-Back airflow
Power supplies 546,260
Mean time between failures (MTBF) (hours)
1 Measured from the front of the chassis (excluding handles from the power supply, fan tray, and interface modules installed in the chassis).
Power consumption Max 145W, Typical: 110W
AC input voltage and frequency Voltage range: 85V AC to 264V AC, nominal 100V AC to 240V AC

Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz

DC input voltage Voltage range: -18 to -32 VDC or -36 to -72 VDC, nominal: -24 VDC/-48 VDC
Operating environment and altitude1 -40 to 70ºC, up to 1,000 feet (300m)

-40 to 65ºC, up to 6,000 feet (1800m)

-40 to 55ºC, up to 13,000 feet (4000m)

Relative humidity 5 to 95 percent, noncondensing
Acoustic noise2 Acoustic noise peak operation compliant to the Network Equipment Building Standards (NEBS) GR-63-Core Issue 3 sound power level of 78 dB at 27ºC operation as measured by the ANSI S12.10/ISO 7779 NAIS noise measurement test standard.
Storage environment Temperature: -40 to 70ºC altitude: 15,000 feet (4570m)
Seismic Zone 4
Safety
●  UL 60950-1, 2005
●  CAN/CSA C22.2 No. 60950-1: 2005
●  IEC 60950-1, 2005
●  EN 60950-1, 2005
●  AS/NZS 60950.1:2005
Electromagnetic ●  FCC CFR47 Part 15 Class A
Emissions compliance
●  EN55022, class A
●  CISPR22, class A
●  ICES-003, class A
●  EN 300 386, class A
●  VCCI, class A
●  KN22, class A
●  EN61000-3-2 to EN61000-3-3
Immunity compliance
●  EN 300 386
●  EN 61000-6-1
●  EN 50082-1
●  CISPR24
●  EN 55024
●  KN 24
●  EN 50121-4
●  EN/KN 61000-4-2 to EN/KN 61000-4-6
●  EN/KN 61000-4-8
●  EN/KN 61000-4-11
Power substation system compliance
●  IEC-61850-3 (2002) (ASR-920-12SZ-IM)
●  IEEE1613 (2009) (ASR-920-12SZ-IM)
NEBS1
●  GR-63-CORE
●  GR-1089-CORE
●  SR-3580 NEBS Level 4
ETSI
●  ETS/EN 300 119 Part 4
●  ETS/EN 300 019 – Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2
●  ETS/EN 300 753
Network synchronization
●  ANSI T1.101
●  GR-1244-CORE
●  GR-253-CORE
●  ITU-T G.703 clause 5
●  ITU-T G.703 clause 9
●  ITU-T G.781
●  ITU-T G.813
●  ITU-T G.823
●  ITU-T G.824
●  ITU-T G.8261/Y.1361
●  ITU-T G.8262
●  ITU-T G.8264
●  IEEE1588-2008
1 Notable exceptions: Fans do not have filters, and all cabling is provided through the front panel