| Physical Specifications | Height: 36.75 in. (933.45 mm) (21 RU) Width: 17.38 in. (441.45 mm) Depth: With doors: 29.03 in. (737.4 mm); Without doors: 28.24 in. (717.3 mm) |
| Slot Orientation | Vertical |
| Series RSP | Dual redundant RSPs with integrated fabric in 2 slots |
| Series Line Cards | 8 line-card slots |
| Common Components | 2 RSPs 2 fan trays 2 PEMs (either DC or AC) 1 fan filter |
| Reliability and Availability | Fabric redundancy Fan redundancy Feed redundancy Power-supply redundancy RSP redundancy Software redundancy |
| Rack Mounting | 19-in. default 21- and 23-in. adapters available Note: Minimum 17.75-in. opening between posts is needed for proper operation |
| Cabinet Mounting | Yes Note: Doors not recommended in enclosed cabinets |
| Wall Mounting | No |
| Airflow | Front-to-back |
| Fabric | One per RSP: Active/active nonblocking operation mode in dual-RSP redundant configuration Fully redundant in dual-RSP redundant configuration Built-in service-intelligence and traffic-prioritization capability |
| Thermal | Two fan trays: 12 high-efficiency fans per tray Variable-speed fans for optimal thermal performance No single point of failure |
| Modularity | Pay-as-you-grow power for future scalability, available in AC and DC. Multiple power module types: 6 kW and 3 kW AC power modules 4.4 kW and 2.1 kW DC power modules Note: Mixing of AC and DC modules is not supported |
| Redundancy | AC: N+N redundancy DC: N+1 redundancy Power module redundancy A/B Feed redundancy PEM redundancy |
| Power Zones | No power zone restrictions Fully load-sharing power infrastructure |
| Power Input | Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum) Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum) |
| Power-Module Airflow | Front-to-back |
| Operating Temperature (Nominal) | 41 to 104°F (5 to 40°C) |
| Operating Temperature (Short-Term) | ASR 9006: 23 to 131°F (-5 to 55°C) ASR 9010: 23 to 122°F (-5 to 50°C) |
| Operating Humidity (Nominal) | 5 to 90% |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Storage (Relative Humidity) | 5 to 93% |
| Operating Altitude | -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Network Equipment Building Standards (NEBS) | SR-3580: NEBS Criteria Levels (Level 3) GR-1089-CORE: NEBS EMC and Safety GR-63-CORE: NEBS Physical Protection VZ.TPR.9205: Verizon TEEER |
| ETSI Standards | EN300 386: Telecommunications Network Equipment (EMC) ETSI 300 019 Storage Class 1.1 ETSI 300 019 Transportation Class 2.3 ETSI 300 019 Stationary Use Class 3.1 |
| EMC Standards Emission | FCC Class 47CFR15 A ICES 003 Class A AS/NZS CISRP22 Class A CISPR 22 (EN55022) Class A VCCI Class A BSMI Class A IEC/EN 61000-3-12: Power Line Harmonics IEC/EN 61000-3-11: Voltage Fluctuations and Flicker EN55022: Information Technology Equipment (Emissions) EN 50121-4: Railway EMC |
| EMC Standards Immunity | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) IEC/EN-61000-4-3: Radiated Immunity (10V/m) IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) IEC/EN-61000-4-5: Signal Surge Ports (1kV) IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM) IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations EN55024: Information Technology Equipment (Immunity) EN50082-1/EN-61000-6-1: Generic Immunity Standard EN 50121-4: Railway EMC |
| Safety | UL/CSA/IEC/EN 60950-1 IEC/EN 60825 Laser Safety ACA TS001 AS/NZS 60950 FDA Code of Federal Regulations Laser Safety |
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.