| Model | ASR-9006-AC |
| Brand | Cisco |
| Physical Specifications | Height: 17.50 in (444.5 mm) (10 RU) Width: 17.38 in (441.45 mm) Depth: 29.05 in (737.9 mm) with or without doors |
| Slot Orientation | Horizontal |
| Cisco ASR 9000 Series RSP | Dual redundant RSPs with integrated fabric in 2 slots |
| Cisco ASR 9000 Series Line Cards | 4 line-card slots |
| Common Components | 2 RSPs 2 fan trays 1 PEM (either DC or AC) 1 fan filter |
| Reliability and Availability | Fabric redundancy Fan redundancy Feed redundancy Power-supply redundancy RSP redundancy Software redundancy |
| Rack Mounting | 19-in. default 21- and 23-in. adapters available Minimum 17.75-in. opening between posts required |
| Cabinet Mounting | Yes Doors not recommended in enclosed cabinets |
| Wall Mounting | No |
| Airflow | Right-to-back, Front-to-back with baffle |
| Fabric | One per RSP: Active/active nonblocking operation mode in dual-RSP redundant configuration Fully redundant in dual-RSP redundant configuration Built-in service-intelligence and traffic-prioritization capability |
| Thermal | Two fan trays: 6 high-efficiency fans per tray Variable-speed fans for optimal thermal performance No single point of failure |
| Modularity | Pay-as-you-grow power for future scalability, available in AC and DC Multiple power module types: 3 kW AC power module 2.1 kW DC power module Mixing of AC and DC modules is not supported |
| Redundancy | AC: N+N redundancy DC: N+1 redundancy Power module redundancy A/B Feed redundancy |
| Power Zones | No power zone restrictions, Fully load-sharing power infrastructure |
| Power Input | Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum) Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum) |
| Power-Module Airflow | Front-to-back |
| Operating Temperature (Nominal) | 41 to 104°F (5 to 40°C) |
| Operating Temperature (Short-Term) | ASR 9006: 23 to 131°F (-5 to 55°C) ASR 9010: 23 to 122°F (-5 to 50°C) |
| Operating Humidity (Nominal) | 5 to 90% (relative humidity) |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Storage (Relative Humidity) | 5 to 93% |
| Operating Altitude | -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Network Equipment Building Standards (NEBS) | Cisco ASR 9006 is designed to meet: SR-3580: NEBS Criteria Levels (Level 3) GR-1089-CORE: NEBS EMC and Safety GR-63-CORE: NEBS Physical Protection VZ.TPR.9205: Verizon TEEER |
| ETSI Standards | Cisco ASR 9006 is designed to meet: EN300 386: Telecommunications Network Equipment (EMC) ETSI 300 019 Storage Class 1.1 ETSI 300 019 Transportation Class 2.3 ETSI 300 019 Stationary Use Class 3.1 |
| EMC Standards Emission | Cisco ASR 9006 is designed to meet: FCC Class 47CFR15 A ICES 003 Class A AS/NZS CISRP22 Class A CISPR 22 (EN55022) Class A VCCI Class A BSMI Class A |
| EMC Standards Immunity | Cisco ASR 9006 is designed to meet: IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) IEC/EN-61000-4-3: Radiated Immunity (10V/m) IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) |
| Safety | Cisco ASR 9006 is designed to meet: UL/CSA/IEC/EN 60950-1 IEC/EN 60825 Laser Safety ACA TS001 AS/NZS 60950 FDA Code of Federal Regulations Laser Safety |