A9K-RSP5-TR Specifications |
||
| Part numbers of supported line cards | 5th Generation
● A99-4T-FC
● A99-10X400GE-X-SE
● A99-10X400GE-X-TR
● A99-32HG-FC
● A99-32X100GE-X-SE
● A99-32X100GE-X-TR
● A9K-20HG-FLEX-FC
● A9K-20HG-FLEX-SE
● A9K-20HG-FLEX-TR
● A9K-8HG-FLEX-FC
● A9K-8HG-FLEX-SE
● A9K-8HG-FLEX-TR
● A99-4HG-FLEX-FC
● A99-4HG-FLEX-SE
● A99-4HG-FLEX-TR
● A9K-4HG-FLEX-FC
● A9K-4HG-FLEX-SE
● A9K-4HG-FLEX-TR
4th Generation ● A99-32X100GE-FC
● A99-32X100GE-TR
● A99-32X100GE-CM
● A9K-16X100GE-FC
● A9K-16X100GE-TR
● A9K-16X100GE-CM
● A99-16X100GE-X-FC
● A99-16X100GE-X-SE
|
3rd Generation
● A99-12X100GE-FC
● A99-12X100GE
● A99-12X100GE-CM
● A99-8X100GE-FC
● A99-8X100GE-SE
● A99-8X100GE-TR
● A99-8X100GE-CM
● A9K-8X100GE-FC
● A9K-8X100GE-SE
● A9K-8X100GE-TR
● A9K-8X100GE-CM
● A9K-8X100G-LB-SE
● A9K-8X100G-LB-TR
● A9K-4X100GE-FC
● A9K-4X100GE-SE
● A9K-4X100GE-TR
● A9K-400GE-LAN-FC
● A9K-4X100GE
● A99-48X10GE-1G-FC
● A99-48X10GE-1G-TR
● A99-48X10GE-1G-SE
● A9K-48X10GE-1G-FC
● A9K-48X10GE-1G-TR
● A9K-48X10GE-1G-SE
● A9K-48X10GE-1G-CM
● A9K-24X10GE-1G-FC
● A9K-24X10GE-1G-TR
● A9K-24X10GE-1G-SE
● A9K-24X10GE-1G-CM
● A9K-MOD400-FC
● A9K-MOD400-SE
● A9K-MOD400-TR
● A9K-MOD400-CM
● A9K-MOD200-FC
● A9K-MOD200-SE
● A9K-MOD200-TR
● A9K-400G-DWDM-TR
|
| Redundancy |
● No single point of failure
● 1 + 1 route switch processor redundancy (both route switch processors must be of the same kind)
● Software redundancy
|
|
| Physical specifications (includes ejector bracket/lever) | Each route switch processor occupies 1 slot; a redundant route switch processor configuration occupies 2 slots.
● Height: 1.63 in. (4.10 cm)
● Width: 15.86 in. (40.28 cm)
● Depth: 24.62 in. (62.53 cm)
● Weight: 20.39 lb (9.25 kg)
|
|
|
Environmental Specifications |
||
|
Operating temperature (nominal) |
32 to 104°F (0 to 40°C) |
|
|
Operating temperature |
23 to 131°F (-5 to 55°C) Note: Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year (a total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period). |
|
|
Operating humidity (nominal) (relative humidity) |
5 to 90% |
|
|
Storage temperature |
-40 to 158°F (-40 to 70°C) |
|
|
Storage (relative humidity) |
5 to 93% |
|
|
Operating altitude |
-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
|
|
Compliance |
||
|
Network Equipment Building Standards (NEBS) |
The ASR 9000 Series is designed to meet these standards: ● SR-3580: NEBS Criteria Levels (Level 3)
● GR-1089-CORE: NEBS Electromagnetic Compatibility (EMC) and Safety
● GR-63-CORE: NEBS Physical Protection
● VZ.TPR.9205: Verizon TEEER
|
|
|
ETSI standards |
The ASR 9000 Series is designed to meet these standards: ● EN300 386: Telecommunications Network Equipment (EMC)
● ETSI 300 019 Storage Class 1.1
● ETSI 300 019 Transportation Class 2.3
● ETSI 300 019 Stationary Use Class 3.1
● EN55022: Information Technology Equipment (Emissions)
● EN55024: Information Technology Equipment (Immunity)
● EN50082-1/EN-61000-6-1: Generic Immunity Standard
|
|
|
EMC standards emission |
The ASR 9000 Series is designed to meet these standards: ● FCC Class A
● ICES 003 Class A
● AS/NZS 3548 Class A
● CISPR 22 (EN55022) Class A
● VCCI Class A
● BSMI Class A
● IEC/EN 61000-3-2: Power Line Harmonics
● IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
● EN 50121-4: Railway EMC
|
|
|
EMC standards immunity |
The ASR 9000 Series is designed to meet these standards: ● IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
● IEC/EN-61000-4-3: Radiated Immunity (10V/m)
● IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
● IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
● IEC/EN-61000-4-5: Signal Ports (1kV)
● IEC/EN-61000-4-5: Surge DC Port (1kV)
● IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
● IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
● IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
● EN 50121-4: Railway EMC
|
|
|
Safety |
The ASR 9000 Series is designed to meet these standards: ● UL/CSA/IEC/EN 60950-1
● IEC/EN 60825 Laser Safety
● ACA TS001
● AS/NZS 60950
● FDA: Code of Federal Regulations Laser Safety
|
|
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.