A9K-8HG-FLEX-SE Specification |
|
| Chassis compatibility | Compatible with the Cisco ASR 9006, ASR 9010, ASR 9904, ASR 9906, ASR 9910, ASR 9912, and ASR 9922 chassis |
| Port density | 2 Terabit Line Card: 15 QSFP28 ports capable of 10Gb, 40Gb, and 100Gb Ethernet traffic support. 5 QSFP-DD ports capable of 10Gb, 40Gb, 100Gb, 200Gb, and 400Gb Ethernet traffic support.
0.8 Terabit Line Card: 6 QSFP28 ports capable of 10Gb, 40Gb, and 100Gb Ethernet traffic support. 2 QSFP-DD ports capable of 10Gb, 40Gb, 100Gb, 200Gb, and 400Gb Ethernet traffic support. |
| Ethernet | ● 100-Gbps IEEE 802.3ba compliant
● 100 Gigabit Ethernet PHY monitoring ● 400-Gbos IEEE 802.3bs compliant ● IEEE 802.x flow control ● Full-duplex operation ● Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets |
| Performance | ● 100-Gbps line-rate throughput per QSFP28 port
● 400-Gbps line-rate throughput per QSFP-DD port |
| Options | Each line card is available as either a service-edge-optimized or packet-transport-optimized line card |
| Reliability and availability | Line card Online Insertion and Removal (OIR) support without system impact |
| Physical dimensions(includes ejector bracket/lever); (H x W x D); weight | 2T Service Edge Combo Line Card – 5th Generation: 1.63 x 15.58 x 23.80 in.; 24.15 lb (41.4 x 395.7 x 604.5 mm; 10.95 kg)
2T Packet Transport Combo Line Card – 5th Generation: 1.63 x 15.58 x 23.80 in.; 24.15 lb (est.) (41.4 x 395.7 x 604.5 mm; 10.95 kg) 800G Service Edge Combo Line Card – 5th Generation: 1.63 x 15.58 x 23.80 in.; 21.70 lb (41.4 x 395.7 x 604.5 mm; 9.84 kg) 800G Packet Transport Combo Line Card – 5th Generation: 1.63 x 15.58 x 23.80 in.; 21.70 lb (41.4 x 395.7 x 604.5 mm; 9.84 kg) |
| Operating temperature |
41 to 104°F (5 to 40°C) Note: Limitations may apply when using high-power optics |
|
Operating humidity (nominal) (relative humidity) |
10 to 85% |
|
Storage temperature |
–40 to 158°F (–40 to 70°C) |
|
Storage (relative humidity) |
5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air |
|
Operating altitude |
–60 to 4000 m (up to 2000 m conforms to IEC, EN, UL, and CSA 60950 requirements) |
|
ETSI/EN standards |
Cisco ASR 9000 Series Routers are designed to meet: ● EN300 386: Telecommunications Network Equipment (EMC) ● ETSI 300 019 Storage Class 1.1 ● ETSI 300 019 Transportation Class 2.3 ● ETSI 300 019 Stationary Use Class 3.1 ● EN55022: Information Technology Equipment (Emissions) ● EN55032: Multimedia Equipment (Emissions) ● EN55024: Information Technology Equipment (Immunity) ● EN55035: Multimedia Equipment (Immunity) ● EN50082-1/EN-61000-6-1: Generic Immunity Standard |
|
EMC standards |
Cisco ASR 9000 Series Routers are designed to meet: ● FCC Class A ● ICES 003 Class A ● AS/NZS CISPR 32 Class A ● CISPR 22/CISPR 32 Class A ● EN55022/EN55032 Class A ● CCI Class A ● CNS-13438 Class A ● KN32 Class A ● IEC/EN 61000-3-2: Power Line Harmonics ● IEC/EN 61000-3-3: Voltage Fluctuations and Flicker ● EN50121-4 Railway applications Part 4: Emission and immunity of the signaling and telecommunications apparatus ● EN50121-3-2 Railway applications Part 3-2: Rolling stock – Apparatus |
|
Immunity |
Cisco ASR 9000 Series Routers are designed to meet: ● IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) ● IEC/EN-61000-4-3: Radiated Immunity (10V/m) ● IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) ● IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) ● IEC/EN-61000-4-5: Signal Ports (1kV) ● IEC/EN-61000-4-5: Surge DC Port (1kV) ● IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) ● IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) ● IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations ● KN35 |
|
Safety |
Cisco ASR 9000 Series Routers are designed to meet: ● UL/CSA/IEC/EN 60950-1 ● IEC/EN 60825 Laser Safety ● ACA TS001 ● AS/NZS 60950 ● FDA: Code of Federal Regulations Laser Safety |
|
Network Equipment Building Systems (NEBS) |
Designed to meet: ● SR-3580: NEBS Criteria Levels (Level 3) ● GR-1089-CORE: NEBS EMC and Safety ● GR-63-CORE: NEBS Physical Protection |
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.