| Model | ASR-9010-AC-V2 |
|---|---|
| Brand | Cisco |
| Height | 36.75 in. (933.45 mm) (21 RU) |
| Width | 17.38 in. (441.45 mm) |
| Depth with Doors | 29.03 in. (737.4 mm) |
| Depth without Doors | 28.24 in. (717.3 mm) |
| Slot Orientation | Vertical |
| RSP Configuration | Dual redundant RSPs with integrated fabric in 2 slots |
| Line Card Slots | 8 line-card slots |
| Common Components | 2 RSPs, 2 fan trays, 2 PEMs (either DC or AC), 1 fan filter |
| Fabric Redundancy | Active/active nonblocking operation, Fully redundant, Service-intelligence and traffic-prioritization |
| Thermal | Two fan trays, 12 high-efficiency fans per tray, Variable-speed fans, No single point of failure |
| Modularity | Pay-as-you-grow power (AC and DC), Multiple power module types |
| Redundancy | AC: N+N redundancy, DC: N+1 redundancy, Power module redundancy, A/B Feed redundancy, PEM redundancy |
| Power Zones | No power zone restrictions, Fully load-sharing power infrastructure |
| Power Input | Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum), Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum) |
| Operating Temperature (Nominal) | 5 to 40 °C (41 to 104 °F) |
| Operating Temperature (Short-Term) | ASR 9006: -5 to 55 °C (23 to 131 °F), ASR 9010: -5 to 50 °C (23 to 122 °F) |
| Operating Humidity (Nominal) | 5 to 90% |
| Storage Temperature | -40 to 70 °C (-40 to 158 °F) |
| Storage (Relative Humidity) | 5 to 93% |
| Operating Altitude | -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Rack Mounting | 19-in. default, 21- and 23-in. adapters available, Minimum 17.75-in. opening between posts is needed |
| Cabinet Mounting | Yes, Doors not recommended in enclosed cabinets |
| Wall Mounting | No |
| Airflow | Front-to-back |
| NEBS Standards | SR-3580: NEBS Criteria Levels (Level 3), GR-1089-CORE: NEBS EMC and Safety, GR-63-CORE: NEBS Physical Protection, VZ.TPR.9205: Verizon TEEER |
| ETSI Standards | EN300 386: Telecommunications Network Equipment (EMC), ETSI 300 019 Storage Class 1.1, ETSI 300 019 Transportation Class 2.3, ETSI 300 019 Stationary Use Class 3.1 |
| EMC Standards Emission | FCC Class 47CFR15 A, ICES 003 Class A, AS/NZS CISRP22 Class A, CISPR 22 (EN55022) Class A, VCCI Class A, BSMI Class A, IEC/EN 61000-3-12: Power Line Harmonics, IEC/EN 61000-3-11: Voltage Fluctuations and Flicker, EN55022: Information Technology Equipment (Emissions), EN 50121-4: Railway EMC |
| EMC Standards Immunity | IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air), IEC/EN-61000-4-3: Radiated Immunity (10V/m), IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal), IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM), IEC/EN-61000-4-5: Signal Surge Ports (1kV), IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM), IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms), IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m), IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations, EN55024: Information Technology Equipment (Immunity), EN50082-1/EN-61000-6-1: Generic Immunity Standard, EN 50121-4: Railway EMC |
| Safety | UL/CSA/IEC/EN 60950-1, IEC/EN 60825 Laser Safety, ACA TS001, AS/NZS 60950, FDA Code of Federal Regulations Laser Safety |
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.