A9K-MOD400-SE Specifications |
|
| Chassis compatibility | Compatible with the Cisco ASR 9922, 9912, 9910, 9906, 9904, 9010, and 9006 routers |
| Port density | In the 400G modular line card, up to 2 modular port adapters are supported per line card for up to:
● 40-port 10G or 64-port 1G interfaces
● 4-port 40G interfaces
● 4-port 100G interfaces
In the 200G modular line card, two modular port adapters are supported per line card, except for the 2-port 100 Gigabit modular port adapter and the 20-port 10 Gigabit modular port adapter. The 2-port 100 Gigabit and 20-port 10 Gigabit modular adapters are supported only in bay 0 of the 200G modular line card. The achievable port density on this line card is as follows: ● 20-port 10G or 64-port 1G interfaces
● 4-port 40G interfaces
● 2-port 100G interfaces
|
| Ethernet |
● IEEE 802.3 compliant
● 10 Gigabit Ethernet PHY monitoring
● IEEE 802.x flow control
● Full-duplex operation
● Per-port byte and packet counters for policy drops, oversubscription drops, Cyclic Redundancy Check (CRC) error drops, packet sizes, and unicast, multicast, and broadcast packets
|
| Card density | Maximum number of line cards per system:
● Cisco ASR 9922: 20
● Cisco ASR 9912: 10
● Cisco ASR 9910: 8
● Cisco ASR 9906: 4
● Cisco ASR 9904: 2
● Cisco ASR 9010: 8
● Cisco ASR 9006: 4
|
| Options | Each line card is available as either a service edge – optimized line card (enhanced QoS) or a packet transport – optimized line card (basic QoS) |
| Reliability and availability | Line card Online Insertion and Removal (OIR) support without system impact |
| Network Equipment Building Standards (NEBS) | Cisco ASR 9000 Series Routers are designed to meet:
● SR-3580: NEBS Criteria Levels (Level 3)
● GR-1089-CORE: NEBS EMC and Safety
● GR-63-CORE: NEBS Physical Protection
|
| Operating temperature (nominal) | 41 to 104°F (5 to 40°C) |
| Operating temperature (short-term) |
23 to 131°F (-5 to 55°C) |
| Operating humidity (nominal) relative humidity | 10 to 85% |
| Storage temperature | -40 to 158°F (-40 to 70°C) |
| Storage relative humidity | 5 to 95%
Note: Not to exceed 0.024 kg of water per kg of dry air |
| Operating altitude | -60 to 4000m (up to 2000m conforms to IEC, EN, UL, and CSA 60950 requirements) |
| ETSI standards | Cisco ASR 9000 Series Routers are designed to meet:
● EN300 386: Telecommunications Network Equipment (EMC)
● ETSI 300 019 Storage Class 1.1
● ETSI 300 019 Transportation Class 2.3
● ETSI 300 019 Stationary Use Class 3.1
● EN55022: Information Technology Equipment (Emissions)
● EN55024: Information Technology Equipment (Immunity)
● EN50082-1/EN-61000-6-1: Generic Immunity Standard
|
| EMC standards | Cisco ASR 9000 Series Routers are designed to meet:
● FCC Class A
● ICES 003 Class A
● AS/NZS 3548 Class A
● CISPR 22 (EN55022) Class A
● VCCI Class A
● BSMI Class A
● IEC/EN 61000-3-2: Power Line Harmonics
● IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
|
| Immunity | Cisco ASR 9000 Series Routers are designed to meet:
● IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
● IEC/EN-61000-4-3: Radiated Immunity (10V/m)
● IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
● IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
● IEC/EN-61000-4-5: Signal Ports (1kV)
● IEC/EN-61000-4-5: Surge DC Port (1kV)
● IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
● IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
● IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
|
| Safety | Cisco ASR 9000 Series Routers are designed to meet:
● UL/CSA/IEC/EN 60950-1
● IEC/EN 60825 Laser Safety
● ACA TS001
● AS/NZS 60950
● FDA: Code of Federal Regulations Laser Safety
|
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.