ASR-9912 Specification |
|
| Physical specifications | Height: 52.5 in. (1333.5 mm) (30 RU)
Width: 17.60 in. (447.04 mm) Depth: ● With door: 30.03 in. (762.76 mm)
● Without doors: 29.25 in. (742.95mm)
Weight: ● 231.25 lb (105.11 kg) (3 PEMs and chassis)
● 389.55 lb (177.07 kg) (3 PEMs, 2 Fan Trays, 2 RP2, and 5 Fabric Card 2)
|
| Slot orientation | Vertical |
| Cisco ASR 9000 Series RSP | RSPs segregated into route processor and fabric cards |
| Route processor | Dual redundant route processors in 2 slots |
| Fabric cards | 6 + 1 redundant fabric cards |
| Cisco ASR 9000 Series line cards | 10 line-card slots |
| “Commons” components | 2 route processors
7 fabric cards 2 fan trays 3 PEMs (either DC or AC) 1 center fan filter, 2 side fan filters |
| Reliability and availability | Fabric redundancy
Fan redundancy Feed redundancy Power-supply redundancy Route-processor redundancy Software redundancy |
| Rack mounting | 19-in.
21- and 23-in. adapters available |
| Cabinet mounting | Yes
Note: Doors not recommended in enclosed cabinets |
| Wall mounting | No |
| Airflow | Front-to-back |
| Performance | |
| Fabric | Seven switch fabric card slots:
● Support for 6 + 1 redundancy
● Operate in active/active nonblocking mode
● Built-in service-intelligence and traffic-prioritization capability
|
| Thermal | Two fan trays:
● 12 high-efficiency fans per tray
● Variable-speed fans for optimal thermal performance
● No single point of failure
|
| Power | |
| Modularity | Pay-as-you-grow power for future scalability, available in AC and DC
Multiple power module types: ● 6 kW and 3 kW AC power modules
● 4.4 kW and 2.1 kW DC power modules
Note: Mixing of AC and DC modules is not supported |
| Redundancy |
● AC: N+N redundancy
● DC: N+1 redundancy
● Power module redundancy
● A/B Feed redundancy
● PEM redundancy
|
| Power zones | No power zone restrictions
Fully load-sharing power infrastructure |
| Power input | Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum) |
| Power module airflow | Front-to-back |
| Environmental Specifications (All Entries Applicable to Cisco ASR 9912 and ASR 9922) | |
| Operating temperature (nominal) | 41 to 104°F (5 to 40°C) |
| Operating temperature (short-term) | 23 to 131°F (-5 to 55°C) |
| Operating humidity (nominal) (relative humidity) | 5 to 90% |
| Storage temperature | -40 to 158°F (-40 to 70°C) |
| Storage (relative humidity) | 5 to 93% |
| Operating altitude | -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) |
| Regulatory Compliance (All Entries Applicable to Cisco ASR 9912 and ASR 9922) | |
| Network Equipment Building Standards (NEBS) | Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
● SR-3580: NEBS Criteria Levels (Level 3)
● GR-1089-CORE: NEBS EMC and Safety
● GR-63-CORE: NEBS Physical Protection
● VZ.TPR.9205: Verizon TEEER
|
| ETSI standards | Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
● EN300 386: Telecommunications Network Equipment (EMC)
● ETSI 300 019 Storage Class 1.1
● ETSI 300 019 Transportation Class 2.3
● ETSI 300 019 Stationary Use Class 3.1
|
| EMC standards emission | Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
● FCC Class 47CFR15 A
● ICES 003 Class A
● AS/NZS CISRP22 Class A
● CISPR 22 (EN55022) Class A
● VCCI Class A
● BSMI Class A
● IEC/EN 61000-3-12: Power Line Harmonics
● IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
● EN55022: Information Technology Equipment (Emissions)
● EN 50121-4: Railway EMC
|
| EMC standards immunity | Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
● IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
● IEC/EN-61000-4-3: Radiated Immunity (10V/m)
● IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
● IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
● IEC/EN-61000-4-5: Signal Surge Ports (1kV)
● IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
● IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
● IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
● IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
● EN55024: Information Technology Equipment (Immunity)
● EN50082-1/EN-61000-6-1: Generic Immunity Standard
● EN 50121-4: Railway EMC
|
| Safety | Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
● UL/CSA/IEC/EN 60950-1
● IEC/EN 60825 Laser Safety
● ACA TS001
● AS/NZS 60950
● FDA Code of Federal Regulations Laser Safety
|
Do you have any question or need quotation about this Product? Contact us now via Fast Response Chat or Contact me here.